POWYS 1110
SKU:
606354
Single-phase Energy Analyzer
How can I find pricing information?
To access product pricing information, create an order list and contact us.
Min. order quantity : 1
Packing unit : 1 pcs.
-
Pick up from the Woodmart Store
To pick up today
Free
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
Free
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
Free
-
Warranty 1 year
-
Free 30-Day returns
Commercial Information
Product Sales Code
606354
Packing Unit
1 pcs.
Customs Tariff No.
902830900000
Weight per piece (inc. packing)
0.14 kg.
Product Description
NULL
Technical Information
PRODUCT SPECIFICATIONS
THD (Voltage)
+
THD (Current)
+
GENERAL
Password Protection
+
Voltage Transformer Ratio (VTR)
1 - 5000
Current Transformer Ratio (CTR)
1 - 5000
Measurements per Period
256
LCD Refresh Rate
1 sn.
Networks
TT, TN, IT
Connection Type
1 Faz (1 ak?m trafosu ve nötr ile)
Demand Period
1-60 min. adjustable
Min./Max. Demand Values
+
Protection Class
IP20
Mounting Type
Rail Mounted
Seven-Segment Display
+
ENVIRONMENTAL CONDITIONS
Operating Temperature
-20 to +70°C
Storage Temperature
-30°C +80°C
Relative Humidity (Non-condensing)
Maks. 95%
DIGITAL OUTPUT
Insulation Level
5000 Vrms
Number of Outputs
2
Type
Transistör
Voltage Switching Range
5-30 VDC
Minimum Switching Frequency
20 Hz, 50 ms
CURRENT MEASUREMENT INPUT
Measurement Range
10mA - 6A AC
Overvoltage Category
300 V Cat II
Voltage Fluctuation Measurement
2 kV
Power Consumption
<0.2 VA
Intermittent Overload
100 A for 1 sec
Sampling Frequency Between 45-65 Hz
12,8 kHz
ENERGY MEASUREMENT
Single-Phase Energy Measurement
+
Number of Tariffs
1
VOLTAGE MEASUREMENT INPUT
Overvoltage Category
300 V Cat III
L-N Measurement Range
10-500 Vrms
Frequency Measurement Range
45-65 Hz
Power Consumption
<0.1 VA
Sampling Frequency Between 45-65 Hz
12,8 kHz
POWER QUALITY MEASUREMENTS
Harmonics for Current and Voltage Phases
Up to 31st
MEASUREMENT ACCURACY IEC 61557-12
Total Active Power
Class 0.5
Total Reactive Power
Class 1
Total Reactive Energy
Class 2
Frequency
Class 0.1
Current
Class 0.5
Neutral Current
Class 0.5
Voltage
Class 0.2
Power Factor
Class 0.5
THDv / THDi
Class 1
Total Apparent Power
Class 0.5
Total Active Energy
Class 0.5
MEASUREMENT ACCURACY IEC 62053-22
Total Active Energy
Class 0.5S
MEASUREMENT ACCURACY IEC 62053-23
Total Reactive Energy
Class 2
POWER SUPPLY
Voltage
85-300V AC / 85-300V DC
Frequency
45-65Hz
Consumption
<4VA AC
CABLE CROSS SECTIONS (POWER SUPPLY, VOLTAGE, CURRENT, RELAY OUTPUTS)
With Ferrule
2.5mm² - 14AWG
Without Ferrule
4mm² - 12AWG, 2x1.5mm² - 2x16AWG
CABLE CROSS SECTIONS (DIGITAL I/O, RS485, ANALOG OUTPUTS)
With Ferrule
1.5mm² - 16AWG
Without Ferrule
1.5mm² - 16AWG, 2x0.75mm² - 2x18AWG
Certificates

CE

UKCA

UL
Accessories
PRODUCT SPECIFICATIONS
THD (Voltage)
+
THD (Current)
+
GENERAL
Password Protection
+
Voltage Transformer Ratio (VTR)
1 - 5000
Current Transformer Ratio (CTR)
1 - 5000
Measurements per Period
256
LCD Refresh Rate
1 sn.
Networks
TT, TN, IT
Connection Type
1 Faz (1 ak?m trafosu ve nötr ile)
Demand Period
1-60 min. adjustable
Min./Max. Demand Values
+
Protection Class
IP20
Mounting Type
Rail Mounted
Seven-Segment Display
+
ENVIRONMENTAL CONDITIONS
Operating Temperature
-20 to +70°C
Storage Temperature
-30°C +80°C
Relative Humidity (Non-condensing)
Maks. 95%
DIGITAL OUTPUT
Insulation Level
5000 Vrms
Number of Outputs
2
Type
Transistör
Voltage Switching Range
5-30 VDC
Minimum Switching Frequency
20 Hz, 50 ms
CURRENT MEASUREMENT INPUT
Measurement Range
10mA - 6A AC
Overvoltage Category
300 V Cat II
Voltage Fluctuation Measurement
2 kV
Power Consumption
<0.2 VA
Intermittent Overload
100 A for 1 sec
Sampling Frequency Between 45-65 Hz
12,8 kHz
ENERGY MEASUREMENT
Single-Phase Energy Measurement
+
Number of Tariffs
1
VOLTAGE MEASUREMENT INPUT
Overvoltage Category
300 V Cat III
L-N Measurement Range
10-500 Vrms
Frequency Measurement Range
45-65 Hz
Power Consumption
<0.1 VA
Sampling Frequency Between 45-65 Hz
12,8 kHz
POWER QUALITY MEASUREMENTS
Harmonics for Current and Voltage Phases
Up to 31st
MEASUREMENT ACCURACY IEC 61557-12
Total Active Power
Class 0.5
Total Reactive Power
Class 1
Total Reactive Energy
Class 2
Frequency
Class 0.1
Current
Class 0.5
Neutral Current
Class 0.5
Voltage
Class 0.2
Power Factor
Class 0.5
THDv / THDi
Class 1
Total Apparent Power
Class 0.5
Total Active Energy
Class 0.5
MEASUREMENT ACCURACY IEC 62053-22
Total Active Energy
Class 0.5S
MEASUREMENT ACCURACY IEC 62053-23
Total Reactive Energy
Class 2
POWER SUPPLY
Voltage
85-300V AC / 85-300V DC
Frequency
45-65Hz
Consumption
<4VA AC
CABLE CROSS SECTIONS (POWER SUPPLY, VOLTAGE, CURRENT, RELAY OUTPUTS)
With Ferrule
2.5mm² - 14AWG
Without Ferrule
4mm² - 12AWG, 2x1.5mm² - 2x16AWG
CABLE CROSS SECTIONS (DIGITAL I/O, RS485, ANALOG OUTPUTS)
With Ferrule
1.5mm² - 16AWG
Without Ferrule
1.5mm² - 16AWG, 2x0.75mm² - 2x18AWG

CE

UKCA

UL