POWYS 1120

SKU: 606352

Energy Analyzer, Multi measurement, CT connection, RS485 (Modbus RTU), Custom LCD

Discontinued product. Available while stocks last. Please contact our sales team for current stock availability.


Current version stock code: 606370

How can I find pricing information?

To access product pricing information, create an order list and contact us.

Min. order quantity : 1
Packing unit : 1 pcs.
pcs.

Product Files

×
Technical Information Sheet (TDS) pdf
Technical Information Sheet (TDS) pdf

Download product certificates

×
CE DECLARATION PDF
UKCA DECLARATION PDF
  • Pick up from the Woodmart Store

To pick up today

Free

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

Free

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

Free

  • Warranty 1 year
  • Free 30-Day returns
Commercial Information
Product Sales Code
606352
Packing Unit
1 pcs.
Customs Tariff No.
902830900000
Weight per piece (inc. packing)
0.14 kg.

1Ø Energy Analyzer

PRODUCT SPECIFICATIONS

THD (Voltage)
+
THD (Current)
+

GENERAL

LCD Display
+
Password Protection
+
Voltage Transformer Ratio (VTR)
1 - 5000
Current Transformer Ratio (CTR)
1 - 5000
Measurements per Period
256
LCD Refresh Rate
1 sn.
Networks
TT, TN, IT
Connection Type
1 Faz (1 akim trafosu ve nötr ile)
Demand Period
1-60 min. adjustable
Min./Max. Demand Values
+
Protection Class
IP20
Mounting Type
Rail Mounted

ENVIRONMENTAL CONDITIONS

Operating Temperature
-20 to +70°C
Storage Temperature
-30°C +80°C
Relative Humidity (Non-condensing)
Maks. 95%

COMMUNICATION

Protocol
Modbus RTU
Baud Rate
1200-57600 bps adjustable
Parity
Odd, Even, None
Stop Bit
1
Slave ID
1-247
Insulation
2750V RMS

CURRENT MEASUREMENT INPUT

Measurement Range
10mA - 6A AC
Overvoltage Category
300 V Cat II
Voltage Fluctuation Measurement
2 kV
Power Consumption
<0.2 VA
Intermittent Overload
100 A for 1 sec
Sampling Frequency Between 45-65 Hz
12,8 kHz

ENERGY MEASUREMENT

Single-Phase Energy Measurement
+
Number of Tariffs
11

VOLTAGE MEASUREMENT INPUT

Overvoltage Category
300 V Cat III
L-N Measurement Range
10-500 Vrms
Frequency Measurement Range
45-65 Hz
Power Consumption
<0.1 VA
Sampling Frequency Between 45-65 Hz
12,8 kHz

POWER QUALITY MEASUREMENTS

Harmonics for Current and Voltage Phases
Up to 31st

MEASUREMENT ACCURACY IEC 61557-12

Total Active Power
Class 0.5
Total Reactive Power
Class 1
Total Reactive Energy
Class 2
Frequency
Class 0.1
Current
Class 0.5
Neutral Current
Class 0.5
Voltage
Class 0.2
Power Factor
Class 0.5
THDv / THDi
Class 1
Total Apparent Power
Class 0.5
Total Active Energy
Class 0.5

MEASUREMENT ACCURACY IEC 62053-22

Total Active Energy
Class 0.5S

MEASUREMENT ACCURACY IEC 62053-23

Total Reactive Energy
Class 2

POWER SUPPLY

Voltage
85-300V AC / 85-300V DC
Frequency
45-65Hz
Consumption
<4VA AC

CABLE CROSS SECTIONS (POWER SUPPLY, VOLTAGE, CURRENT, RELAY OUTPUTS)

With Ferrule
2.5mm² - 14AWG
Without Ferrule
4mm² - 12AWG, 2x1.5mm² - 2x16AWG

CABLE CROSS SECTIONS (DIGITAL I/O, RS485, ANALOG OUTPUTS)

With Ferrule
1.5mm² - 16AWG
Without Ferrule
1.5mm² - 16AWG, 2x0.75mm² - 2x18AWG
CE
UKCA
UL

PRODUCT SPECIFICATIONS

THD (Voltage)
+
THD (Current)
+

GENERAL

LCD Display
+
Password Protection
+
Voltage Transformer Ratio (VTR)
1 - 5000
Current Transformer Ratio (CTR)
1 - 5000
Measurements per Period
256
LCD Refresh Rate
1 sn.
Networks
TT, TN, IT
Connection Type
1 Faz (1 akim trafosu ve nötr ile)
Demand Period
1-60 min. adjustable
Min./Max. Demand Values
+
Protection Class
IP20
Mounting Type
Rail Mounted

ENVIRONMENTAL CONDITIONS

Operating Temperature
-20 to +70°C
Storage Temperature
-30°C +80°C
Relative Humidity (Non-condensing)
Maks. 95%

COMMUNICATION

Protocol
Modbus RTU
Baud Rate
1200-57600 bps adjustable
Parity
Odd, Even, None
Stop Bit
1
Slave ID
1-247
Insulation
2750V RMS

CURRENT MEASUREMENT INPUT

Measurement Range
10mA - 6A AC
Overvoltage Category
300 V Cat II
Voltage Fluctuation Measurement
2 kV
Power Consumption
<0.2 VA
Intermittent Overload
100 A for 1 sec
Sampling Frequency Between 45-65 Hz
12,8 kHz

ENERGY MEASUREMENT

Single-Phase Energy Measurement
+
Number of Tariffs
11

VOLTAGE MEASUREMENT INPUT

Overvoltage Category
300 V Cat III
L-N Measurement Range
10-500 Vrms
Frequency Measurement Range
45-65 Hz
Power Consumption
<0.1 VA
Sampling Frequency Between 45-65 Hz
12,8 kHz

POWER QUALITY MEASUREMENTS

Harmonics for Current and Voltage Phases
Up to 31st

MEASUREMENT ACCURACY IEC 61557-12

Total Active Power
Class 0.5
Total Reactive Power
Class 1
Total Reactive Energy
Class 2
Frequency
Class 0.1
Current
Class 0.5
Neutral Current
Class 0.5
Voltage
Class 0.2
Power Factor
Class 0.5
THDv / THDi
Class 1
Total Apparent Power
Class 0.5
Total Active Energy
Class 0.5

MEASUREMENT ACCURACY IEC 62053-22

Total Active Energy
Class 0.5S

MEASUREMENT ACCURACY IEC 62053-23

Total Reactive Energy
Class 2

POWER SUPPLY

Voltage
85-300V AC / 85-300V DC
Frequency
45-65Hz
Consumption
<4VA AC

CABLE CROSS SECTIONS (POWER SUPPLY, VOLTAGE, CURRENT, RELAY OUTPUTS)

With Ferrule
2.5mm² - 14AWG
Without Ferrule
4mm² - 12AWG, 2x1.5mm² - 2x16AWG

CABLE CROSS SECTIONS (DIGITAL I/O, RS485, ANALOG OUTPUTS)

With Ferrule
1.5mm² - 16AWG
Without Ferrule
1.5mm² - 16AWG, 2x0.75mm² - 2x18AWG
CE
UKCA
UL