PRODUCT SPECIFICATIONS
Connection Type
1 Faz (1 akım trafosu ve nötr ile)
Overvoltage Category
300 V Cat II
Power Consumption
<0.2 VA
Overvoltage Category
300 V Cat III
Power Consumption
<0.1 VA
THDv / THDi
Class 1
Baud Rate
1200-57600 bps adjustable
Slave ID
1-247
ENVIRONMENTAL CONDITIONS
Operating Temperature
-20 to +70°C
Storage Temperature
-30°C +80°C
Relative Humidity (Non-condensing)
Maks. 95%
INPUT RATINGS
Frequency
Class 0.1
Frequency
45-65Hz
GENERAL
Password Protection
+
Voltage Transformer Ratio (VTR)
1 - 5000
Current Transformer Ratio (CTR)
1 - 5000
Measurements per Period
256
LCD Refresh Rate
1 sn.
Networks
TT, TN, IT
Demand Period
1-60 min. adjustable
Min./Max. Demand Values
+
Protection Class
IP20
Mounting Type
Rail Mounted
Seven-Segment Display
+
POWER SUPPLY
Voltage
85-300V AC / 85-300V DC
Consumption
<4VA AC
COMMUNICATION
Protocol
Modbus RTU
Parity
Odd, Even, None
Stop Bit
1
Insulation
2750V RMS
ENERGY MEASUREMENT
1-Phase Energy Measurement
+
Number of Tariffs
1
CURRENT MEASUREMENT INPUT
Measurement Range
10mA - 6A AC
Voltage Fluctuation Measurement
2 kV
Intermittent Overload
100 A for 1 sec
Sampling Frequency Between 45-65 Hz
12,8 kHz
VOLTAGE MEASUREMENT INPUT
Measuring Range (L-N)
10-500 Vrms
Frequency Measurement Range
45-65 Hz
Sampling Frequency Between 45-65 Hz
12,8 kHz
POWER QUALITY MEASUREMENTS
THD (Voltage)
+
THD (Current)
+
Harmonics for Current and Voltage Phases
Up to 31st
MEASURING ACCURACY (IEC 61557-12)
Total Active Power
Class 0.5
Total Reactive Power
Class 1
Total Reactive Energy
Class 2
Current
Class 0.5
Neutral Current
Class 0.5
Voltage
Class 0.2
Power Factor
Class 0.5
Total Apparent Power
Class 0.5
Total Active Energy
Class 0.5
MEASURING ACCURACY (IEC 62053-22)
Total Active Energy
Class 0.5S
MEASURING ACCURACY (IEC 62053-23)
Total Reactive Energy
Class 2
CABLE CROSS SECTIONS (POWER SUPPLY, VOLTAGE, CURRENT, RELAY OUTPUTS)
With Ferrule
2.5mm² - 14AWG
Without Ferrule
4mm² - 12AWG, 2x1.5mm² - 2x16AWG
CABLE CROSS SECTIONS (DIGITAL I/O, RS485, ANALOG OUTPUTS)
With Ferrule
1.5mm² - 16AWG
Without Ferrule
1.5mm² - 16AWG, 2x0.75mm² - 2x18AWG
Certificates

CE

UKCA

UL
Accessories
PRODUCT SPECIFICATIONS
Connection Type
1 Faz (1 akım trafosu ve nötr ile)
Overvoltage Category
300 V Cat II
Power Consumption
<0.2 VA
Overvoltage Category
300 V Cat III
Power Consumption
<0.1 VA
THDv / THDi
Class 1
Baud Rate
1200-57600 bps adjustable
Slave ID
1-247
ENVIRONMENTAL CONDITIONS
Operating Temperature
-20 to +70°C
Storage Temperature
-30°C +80°C
Relative Humidity (Non-condensing)
Maks. 95%
INPUT RATINGS
Frequency
Class 0.1
Frequency
45-65Hz
GENERAL
Password Protection
+
Voltage Transformer Ratio (VTR)
1 - 5000
Current Transformer Ratio (CTR)
1 - 5000
Measurements per Period
256
LCD Refresh Rate
1 sn.
Networks
TT, TN, IT
Demand Period
1-60 min. adjustable
Min./Max. Demand Values
+
Protection Class
IP20
Mounting Type
Rail Mounted
Seven-Segment Display
+
POWER SUPPLY
Voltage
85-300V AC / 85-300V DC
Consumption
<4VA AC
COMMUNICATION
Protocol
Modbus RTU
Parity
Odd, Even, None
Stop Bit
1
Insulation
2750V RMS
ENERGY MEASUREMENT
1-Phase Energy Measurement
+
Number of Tariffs
1
CURRENT MEASUREMENT INPUT
Measurement Range
10mA - 6A AC
Voltage Fluctuation Measurement
2 kV
Intermittent Overload
100 A for 1 sec
Sampling Frequency Between 45-65 Hz
12,8 kHz
VOLTAGE MEASUREMENT INPUT
Measuring Range (L-N)
10-500 Vrms
Frequency Measurement Range
45-65 Hz
Sampling Frequency Between 45-65 Hz
12,8 kHz
POWER QUALITY MEASUREMENTS
THD (Voltage)
+
THD (Current)
+
Harmonics for Current and Voltage Phases
Up to 31st
MEASURING ACCURACY (IEC 61557-12)
Total Active Power
Class 0.5
Total Reactive Power
Class 1
Total Reactive Energy
Class 2
Current
Class 0.5
Neutral Current
Class 0.5
Voltage
Class 0.2
Power Factor
Class 0.5
Total Apparent Power
Class 0.5
Total Active Energy
Class 0.5
MEASURING ACCURACY (IEC 62053-22)
Total Active Energy
Class 0.5S
MEASURING ACCURACY (IEC 62053-23)
Total Reactive Energy
Class 2
CABLE CROSS SECTIONS (POWER SUPPLY, VOLTAGE, CURRENT, RELAY OUTPUTS)
With Ferrule
2.5mm² - 14AWG
Without Ferrule
4mm² - 12AWG, 2x1.5mm² - 2x16AWG
CABLE CROSS SECTIONS (DIGITAL I/O, RS485, ANALOG OUTPUTS)
With Ferrule
1.5mm² - 16AWG
Without Ferrule
1.5mm² - 16AWG, 2x0.75mm² - 2x18AWG

CE

UKCA

UL