ECRAS VCF
SKU:
606218
Multimeter
How can I find pricing information?
To access product pricing information, create an order list and contact us.
Min. order quantity : 1
Packing unit : 1 pcs.
-
Pick up from the Woodmart Store
To pick up today
Free
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
Free
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
Free
-
Warranty 1 year
-
Free 30-Day returns
Commercial Information
Product Sales Code
606218
Packing Unit
1 pcs.
Customs Tariff No.
903032009011
Weight per piece (inc. packing)
0.272 kg.
Product Description
Multimeter
Technical Information
GENERAL
Password Protection
+
Voltage Transformer Ratio (VTR)
1 - 5000
Current Transformer Ratio (CTR)
1 - 5000
Measurements per Period
256
LCD Refresh Rate
1 sn.
Networks
TT, TN, IT
Connection Type
3F4T, 3F3T
Four-Quadrant Measurement
4
Min./Max. Demand Values
+
Protection Class
Front IP40 / Rear IP20
Weight (g)
272
Pack Quantity
1
Mounting Type
Panel Mount
Seven-Segment Display
+
ENVIRONMENTAL CONDITIONS
Operating Temperature
-20°C +70°C
Storage Temperature
-30°C +80°C
Relative Humidity (Non-condensing)
Maks. 95%
CURRENT MEASUREMENT INPUT
Measurement Range
10mA - 6A AC
Overvoltage Category
300 V Cat II
Voltage Fluctuation Measurement
2 kV
Power Consumption
<0.2 VA
Intermittent Overload
100 A for 1 sec
Sampling Frequency Between 45-65 Hz
12.8 kHz
VOLTAGE MEASUREMENT INPUT
Overvoltage Category
300 V Cat III
L-N Measurement Range
1-300 Vrms
L-L Measurement Range
2-500 Vrms
Frequency Measurement Range
45-65 Hz
Power Consumption
<0.1 VA
Sampling Frequency Between 45-65 Hz
12.8 kHz
TIME-STAMPED DATA STORAGE
Demand
--
Alarm Records
--
POWER SUPPLY
Voltage
85-300V AC / 85-300V DC
Frequency
45-65Hz
Consumption
<6VA AC / <3W DC
CABLE CROSS SECTIONS (POWER SUPPLY, VOLTAGE, CURRENT, RELAY OUTPUTS)
With Ferrule
2.5mm² - 14AWG
Without Ferrule
4mm² - 12AWG, 2x1.5mm² - 2x16AWG
CABLE CROSS SECTIONS (DIGITAL I/O, RS485, ANALOG OUTPUTS)
With Ferrule
1.5mm² - 16AWG
Without Ferrule
1.5mm² - 16AWG, 2x0.75mm² - 2x18AWG
EMC/EMI
300 V AC CAT II According to IEC 61010-1
+
EN 55011+A1
2010, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN61000-4-11
Certificates

CE

UKCA

UL
Accessories
GENERAL
Password Protection
+
Voltage Transformer Ratio (VTR)
1 - 5000
Current Transformer Ratio (CTR)
1 - 5000
Measurements per Period
256
LCD Refresh Rate
1 sn.
Networks
TT, TN, IT
Connection Type
3F4T, 3F3T
Four-Quadrant Measurement
4
Min./Max. Demand Values
+
Protection Class
Front IP40 / Rear IP20
Weight (g)
272
Pack Quantity
1
Mounting Type
Panel Mount
Seven-Segment Display
+
ENVIRONMENTAL CONDITIONS
Operating Temperature
-20°C +70°C
Storage Temperature
-30°C +80°C
Relative Humidity (Non-condensing)
Maks. 95%
CURRENT MEASUREMENT INPUT
Measurement Range
10mA - 6A AC
Overvoltage Category
300 V Cat II
Voltage Fluctuation Measurement
2 kV
Power Consumption
<0.2 VA
Intermittent Overload
100 A for 1 sec
Sampling Frequency Between 45-65 Hz
12.8 kHz
VOLTAGE MEASUREMENT INPUT
Overvoltage Category
300 V Cat III
L-N Measurement Range
1-300 Vrms
L-L Measurement Range
2-500 Vrms
Frequency Measurement Range
45-65 Hz
Power Consumption
<0.1 VA
Sampling Frequency Between 45-65 Hz
12.8 kHz
TIME-STAMPED DATA STORAGE
Demand
--
Alarm Records
--
POWER SUPPLY
Voltage
85-300V AC / 85-300V DC
Frequency
45-65Hz
Consumption
<6VA AC / <3W DC
CABLE CROSS SECTIONS (POWER SUPPLY, VOLTAGE, CURRENT, RELAY OUTPUTS)
With Ferrule
2.5mm² - 14AWG
Without Ferrule
4mm² - 12AWG, 2x1.5mm² - 2x16AWG
CABLE CROSS SECTIONS (DIGITAL I/O, RS485, ANALOG OUTPUTS)
With Ferrule
1.5mm² - 16AWG
Without Ferrule
1.5mm² - 16AWG, 2x0.75mm² - 2x18AWG
EMC/EMI
300 V AC CAT II According to IEC 61010-1
+
EN 55011+A1
2010, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN61000-4-11

CE

UKCA

UL