ECRAS 100

SKU: 606210

Multimeter

How can I find pricing information?

To access product pricing information, create an order list and contact us.

Min. order quantity : 1
Packing unit : 1 pcs.
pcs.

Product Files

×
Technical Information Sheet (TDS) pdf
Technical Information Sheet (TDS) pdf

Download product certificates

×
TSE CERTIFICATE PDF
CE DECLARATION PDF
UKCA DECLARATION PDF
  • Pick up from the Woodmart Store

To pick up today

Free

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

Free

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

Free

  • Warranty 1 year
  • Free 30-Day returns
Commercial Information
Product Sales Code
606210
Packing Unit
1 pcs.
Customs Tariff No.
903032009011
Weight per piece (inc. packing)
0.272 kg.

Multimeter

GENERAL

Password Protection
+
Voltage Transformer Ratio (VTR)
1 - 5000
Current Transformer Ratio (CTR)
1 - 5000
Measurements per Period
256
LCD Refresh Rate
1 sn.
Networks
TT, TN, IT
Connection Type
3F4T, 3F3T
Four-Quadrant Measurement
4
Min./Max. Demand Values
+
Protection Class
Front IP40 / Rear IP20
Weight (g)
272
Pack Quantity
1
Mounting Type
Panel Mount
Seven-Segment Display
+

ENVIRONMENTAL CONDITIONS

Operating Temperature
-20°C +70°C
Storage Temperature
-30°C +80°C
Relative Humidity (Non-condensing)
Maks. 95%

CURRENT MEASUREMENT INPUT

Measurement Range
10mA - 6A AC
Overvoltage Category
300 V Cat II
Voltage Fluctuation Measurement
2 kV
Power Consumption
<0.2 VA
Intermittent Overload
100 A for 1 sec
Sampling Frequency Between 45-65 Hz
12.8 kHz

VOLTAGE MEASUREMENT INPUT

Overvoltage Category
300 V Cat III
L-N Measurement Range
1-300 Vrms
L-L Measurement Range
2-500 Vrms
Frequency Measurement Range
45-65 Hz
Power Consumption
<0.1 VA
Sampling Frequency Between 45-65 Hz
12.8 kHz

Diagrams

3-Wire (with 2 CT) - Note
CTs can be connected to any phase. In the figure, they are connected to Phase-1 and Phase-3.
Single-Phase + Neutral Connection with 1 CT
CT and VT can be connected to any phase. In the figure, they are connected to Phase-1.

TIME-STAMPED DATA STORAGE

Demand
--
Alarm Records
--

POWER SUPPLY

Voltage
85-300V AC / 85-300V DC
Frequency
45-65Hz
Consumption
<6VA AC / <3W DC

CABLE CROSS SECTIONS (POWER SUPPLY, VOLTAGE, CURRENT, RELAY OUTPUTS)

With Ferrule
2.5mm² - 14AWG
Without Ferrule
4mm² - 12AWG, 2x1.5mm² - 2x16AWG

EMC/EMI

300 V AC CAT II According to IEC 61010-1
+
EN 55011+A1
2010, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN61000-4-11
CE
UKCA
UL

GENERAL

Password Protection
+
Voltage Transformer Ratio (VTR)
1 - 5000
Current Transformer Ratio (CTR)
1 - 5000
Measurements per Period
256
LCD Refresh Rate
1 sn.
Networks
TT, TN, IT
Connection Type
3F4T, 3F3T
Four-Quadrant Measurement
4
Min./Max. Demand Values
+
Protection Class
Front IP40 / Rear IP20
Weight (g)
272
Pack Quantity
1
Mounting Type
Panel Mount
Seven-Segment Display
+

ENVIRONMENTAL CONDITIONS

Operating Temperature
-20°C +70°C
Storage Temperature
-30°C +80°C
Relative Humidity (Non-condensing)
Maks. 95%

CURRENT MEASUREMENT INPUT

Measurement Range
10mA - 6A AC
Overvoltage Category
300 V Cat II
Voltage Fluctuation Measurement
2 kV
Power Consumption
<0.2 VA
Intermittent Overload
100 A for 1 sec
Sampling Frequency Between 45-65 Hz
12.8 kHz

VOLTAGE MEASUREMENT INPUT

Overvoltage Category
300 V Cat III
L-N Measurement Range
1-300 Vrms
L-L Measurement Range
2-500 Vrms
Frequency Measurement Range
45-65 Hz
Power Consumption
<0.1 VA
Sampling Frequency Between 45-65 Hz
12.8 kHz

Diagrams

3-Wire (with 2 CT) - Note
CTs can be connected to any phase. In the figure, they are connected to Phase-1 and Phase-3.
Single-Phase + Neutral Connection with 1 CT
CT and VT can be connected to any phase. In the figure, they are connected to Phase-1.

TIME-STAMPED DATA STORAGE

Demand
--
Alarm Records
--

POWER SUPPLY

Voltage
85-300V AC / 85-300V DC
Frequency
45-65Hz
Consumption
<6VA AC / <3W DC

CABLE CROSS SECTIONS (POWER SUPPLY, VOLTAGE, CURRENT, RELAY OUTPUTS)

With Ferrule
2.5mm² - 14AWG
Without Ferrule
4mm² - 12AWG, 2x1.5mm² - 2x16AWG

EMC/EMI

300 V AC CAT II According to IEC 61010-1
+
EN 55011+A1
2010, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN61000-4-11
CE
UKCA
UL