POWYS 1110

SKU: 606354

Single-phase Energy Analyzer

How can I find pricing information?

To access product pricing information, create an order list and contact us.

Min. order quantity : 1
Packing unit : 1 pcs.
pcs.

Product Files

×
Technical Information Sheet (TDS) pdf
Technical Information Sheet (TDS) pdf

Download product certificates

×
CE DECLARATION PDF
UKCA DECLARATION PDF
  • Pick up from the Woodmart Store

To pick up today

Free

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

Free

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

Free

  • Warranty 1 year
  • Free 30-Day returns
Commercial Information
Product Sales Code
606354
Packing Unit
1 pcs.
Customs Tariff No.
902830900000
Weight per piece (inc. packing)
0.14 kg.

NULL

PRODUCT SPECIFICATIONS

THD (Voltage)
+
THD (Current)
+

GENERAL

Password Protection
+
Voltage Transformer Ratio (VTR)
1 - 5000
Current Transformer Ratio (CTR)
1 - 5000
Measurements per Period
256
LCD Refresh Rate
1 sn.
Networks
TT, TN, IT
Connection Type
1 Faz (1 ak?m trafosu ve nötr ile)
Demand Period
1-60 min. adjustable
Min./Max. Demand Values
+
Protection Class
IP20
Mounting Type
Rail Mounted
Seven-Segment Display
+

ENVIRONMENTAL CONDITIONS

Operating Temperature
-20 to +70°C
Storage Temperature
-30°C +80°C
Relative Humidity (Non-condensing)
Maks. 95%

DIGITAL OUTPUT

Insulation Level
5000 Vrms
Number of Outputs
2
Type
Transistör
Voltage Switching Range
5-30 VDC
Minimum Switching Frequency
20 Hz, 50 ms

CURRENT MEASUREMENT INPUT

Measurement Range
10mA - 6A AC
Overvoltage Category
300 V Cat II
Voltage Fluctuation Measurement
2 kV
Power Consumption
<0.2 VA
Intermittent Overload
100 A for 1 sec
Sampling Frequency Between 45-65 Hz
12,8 kHz

ENERGY MEASUREMENT

Single-Phase Energy Measurement
+
Number of Tariffs
1

VOLTAGE MEASUREMENT INPUT

Overvoltage Category
300 V Cat III
L-N Measurement Range
10-500 Vrms
Frequency Measurement Range
45-65 Hz
Power Consumption
<0.1 VA
Sampling Frequency Between 45-65 Hz
12,8 kHz

POWER QUALITY MEASUREMENTS

Harmonics for Current and Voltage Phases
Up to 31st

MEASUREMENT ACCURACY IEC 61557-12

Total Active Power
Class 0.5
Total Reactive Power
Class 1
Total Reactive Energy
Class 2
Frequency
Class 0.1
Current
Class 0.5
Neutral Current
Class 0.5
Voltage
Class 0.2
Power Factor
Class 0.5
THDv / THDi
Class 1
Total Apparent Power
Class 0.5
Total Active Energy
Class 0.5

MEASUREMENT ACCURACY IEC 62053-22

Total Active Energy
Class 0.5S

MEASUREMENT ACCURACY IEC 62053-23

Total Reactive Energy
Class 2

POWER SUPPLY

Voltage
85-300V AC / 85-300V DC
Frequency
45-65Hz
Consumption
<4VA AC

CABLE CROSS SECTIONS (POWER SUPPLY, VOLTAGE, CURRENT, RELAY OUTPUTS)

With Ferrule
2.5mm² - 14AWG
Without Ferrule
4mm² - 12AWG, 2x1.5mm² - 2x16AWG

CABLE CROSS SECTIONS (DIGITAL I/O, RS485, ANALOG OUTPUTS)

With Ferrule
1.5mm² - 16AWG
Without Ferrule
1.5mm² - 16AWG, 2x0.75mm² - 2x18AWG
CE
UKCA
UL

PRODUCT SPECIFICATIONS

THD (Voltage)
+
THD (Current)
+

GENERAL

Password Protection
+
Voltage Transformer Ratio (VTR)
1 - 5000
Current Transformer Ratio (CTR)
1 - 5000
Measurements per Period
256
LCD Refresh Rate
1 sn.
Networks
TT, TN, IT
Connection Type
1 Faz (1 ak?m trafosu ve nötr ile)
Demand Period
1-60 min. adjustable
Min./Max. Demand Values
+
Protection Class
IP20
Mounting Type
Rail Mounted
Seven-Segment Display
+

ENVIRONMENTAL CONDITIONS

Operating Temperature
-20 to +70°C
Storage Temperature
-30°C +80°C
Relative Humidity (Non-condensing)
Maks. 95%

DIGITAL OUTPUT

Insulation Level
5000 Vrms
Number of Outputs
2
Type
Transistör
Voltage Switching Range
5-30 VDC
Minimum Switching Frequency
20 Hz, 50 ms

CURRENT MEASUREMENT INPUT

Measurement Range
10mA - 6A AC
Overvoltage Category
300 V Cat II
Voltage Fluctuation Measurement
2 kV
Power Consumption
<0.2 VA
Intermittent Overload
100 A for 1 sec
Sampling Frequency Between 45-65 Hz
12,8 kHz

ENERGY MEASUREMENT

Single-Phase Energy Measurement
+
Number of Tariffs
1

VOLTAGE MEASUREMENT INPUT

Overvoltage Category
300 V Cat III
L-N Measurement Range
10-500 Vrms
Frequency Measurement Range
45-65 Hz
Power Consumption
<0.1 VA
Sampling Frequency Between 45-65 Hz
12,8 kHz

POWER QUALITY MEASUREMENTS

Harmonics for Current and Voltage Phases
Up to 31st

MEASUREMENT ACCURACY IEC 61557-12

Total Active Power
Class 0.5
Total Reactive Power
Class 1
Total Reactive Energy
Class 2
Frequency
Class 0.1
Current
Class 0.5
Neutral Current
Class 0.5
Voltage
Class 0.2
Power Factor
Class 0.5
THDv / THDi
Class 1
Total Apparent Power
Class 0.5
Total Active Energy
Class 0.5

MEASUREMENT ACCURACY IEC 62053-22

Total Active Energy
Class 0.5S

MEASUREMENT ACCURACY IEC 62053-23

Total Reactive Energy
Class 2

POWER SUPPLY

Voltage
85-300V AC / 85-300V DC
Frequency
45-65Hz
Consumption
<4VA AC

CABLE CROSS SECTIONS (POWER SUPPLY, VOLTAGE, CURRENT, RELAY OUTPUTS)

With Ferrule
2.5mm² - 14AWG
Without Ferrule
4mm² - 12AWG, 2x1.5mm² - 2x16AWG

CABLE CROSS SECTIONS (DIGITAL I/O, RS485, ANALOG OUTPUTS)

With Ferrule
1.5mm² - 16AWG
Without Ferrule
1.5mm² - 16AWG, 2x0.75mm² - 2x18AWG
CE
UKCA
UL