KLEA 322P
SKU:
606102
Energy Analyzer
How can I find pricing information?
To access product pricing information, create an order list and contact us.
Min. order quantity : 1
Packing unit : 1 pcs.
-
Pick up from the Woodmart Store
To pick up today
Free
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
Free
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
Free
-
Warranty 1 year
-
Free 30-Day returns
Commercial Information
Product Sales Code
606102
Packing Unit
1 pcs.
Customs Tariff No.
903032009011
Weight per piece (inc. packing)
0.428 kg.
Product Description
Energy Analyzer
Technical Information
PRODUCT SPECIFICATIONS
Connection Type
3F4T, 3F3T, Aron
Overvoltage Category
300 V Cat II
Power Consumption
<0.2 VA
Overvoltage Category
300 V Cat III
Power Consumption
<0.1 VA
THDv / THDi
Class 1
Baud Rate
2400-115200 bps adjustable
Slave ID
1-247
Demand
4 Months x 16 Different Parameters
ENVIRONMENTAL CONDITIONS
Operating Temperature
-20 to +70°C
Storage Temperature
-30°C +80°C
Relative Humidity (Non-condensing)
Maks. 95%
INPUT RATINGS
Frequency
Class 0.05
Frequency
45-65Hz
EMC/EMI
300 V AC CAT II According to IEC 61010-1
+
EN 55011+A1
2010, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN61000-4-11
GENERAL
LCD Display
+
Language Support
Turkish, English, Russian
Password Protection
+
Voltage Transformer Ratio (VTR)
1 - 5000
Current Transformer Ratio (CTR)
1 - 5000
Measurements per Period
512
LCD Refresh Rate
1 sn.
Networks
TT, TN, IT
Signal Waveforms
+
Battery
+
Real-Time Clock
+
Four-Quadrant Measurement
4
Demand Period
1-60 min. adjustable
Phase Diagram
+
Min./Max. Demand Values
+
Protection Class
Front IP40 / Rear IP20
Weight (g)
428
Mounting Type
Panel Mount
POWER SUPPLY
Voltage
85-300V AC / 85-300V DC
Consumption
<3VA AC / <2.5W DC
COMMUNICATION
Protocol
Modbus RTU
Parity
None
Stop Bit
1
Insulation
2750V RMS
ENERGY MEASUREMENT
Multiple Sub-Tariffs (Peak, On-Peak, Off-Peak)
+
3-Phase Energy Measurement
+
Number of Tariffs
2
CURRENT MEASUREMENT INPUT
Measurement Range
10mA - 6A AC
Voltage Fluctuation Measurement
2 kV
Intermittent Overload
100 A for 1 sec
Sampling Frequency Between 45-65 Hz
25.6 kHz
VOLTAGE MEASUREMENT INPUT
Measuring Range (L-N)
1-300 Vrms
Measuring Range (L-L)
2-500 Vrms
Frequency Measurement Range
45-65 Hz
Sampling Frequency Between 45-65 Hz
25.6 kHz
POWER QUALITY MEASUREMENTS
THD (Voltage)
+
THD (Current)
+
Harmonics for Current and Voltage Phases
Up to 51st
MEASURING ACCURACY (IEC 61557-12)
Total Active Power
Class 0.2
Total Reactive Power
Class 1
Total Reactive Energy
Class 2
Current
Class 0.2
Neutral Current
Class 0.5
Voltage
Class 0.2
Power Factor
Class 0.5
Total Apparent Power
Class 0.2
Total Active Energy
Class 0.5
MEASURING ACCURACY (IEC 62053-22)
Total Active Energy
Class 0.2S
MEASURING ACCURACY (IEC 62053-23)
Total Reactive Energy
Class 2
ALARM RELAY OUTPUTS
Number of Outputs
2
type
NO (SPST)
Max. Switching Current
10 A
Max. Switching Voltage
250 VAC
Max. Switching Power
1250 VA
DIAGRAMS
3-Wire (with 2 CT) - Note
CTs can be connected to any phase. In the figure, they are connected to Phase-1 and Phase-3.
Single Phase (with 1 CT) - Note
CT and VT can be connected to any phase. In the figure, they are connected to Phase-1.
TIME-STAMPED DATA STORAGE
Hourly Records
1920 Hours x 68 Different Paramaters
Daily Records
240 Days x 68 Different Paramaters
Monthly Records
36 Months x 68 Different Parameters
Alarm Records
50
DIGITAL OUTPUT
Insulation Level
5000 Vrms
Number of Outputs
2
type
Transistör
Voltage Switching Range
5-30 VDC
Minimum Switching Frequency
20 Hz, 50 ms
DIGITAL INPUT
Number of Inputs
2
Insulation Level
5000 Vrms
Minimum Counting Frequency
100 Hz, 10 ms
Input Type
Dry Contact
CABLE CROSS SECTIONS (POWER SUPPLY, VOLTAGE, CURRENT, RELAY OUTPUTS)
With Ferrule
2.5mm² - 14AWG
Without Ferrule
4mm² - 12AWG, 2x1.5mm² - 2x16AWG
CABLE CROSS SECTIONS (DIGITAL I/O, RS485, ANALOG OUTPUTS)
With Ferrule
1.5mm² - 16AWG
Without Ferrule
1.5mm² - 16AWG, 2x0.75mm² - 2x18AWG
ANALOG OUTPUT
Number of Outputs
2
Output Ranges (0-5V, 0-10V, ±5V, ±10V, 0-20mA, 4-20mA)
Var
Insulation
Isolated
Certificates

CE

UKCA

UL
Accessories
PRODUCT SPECIFICATIONS
Connection Type
3F4T, 3F3T, Aron
Overvoltage Category
300 V Cat II
Power Consumption
<0.2 VA
Overvoltage Category
300 V Cat III
Power Consumption
<0.1 VA
THDv / THDi
Class 1
Baud Rate
2400-115200 bps adjustable
Slave ID
1-247
Demand
4 Months x 16 Different Parameters
ENVIRONMENTAL CONDITIONS
Operating Temperature
-20 to +70°C
Storage Temperature
-30°C +80°C
Relative Humidity (Non-condensing)
Maks. 95%
INPUT RATINGS
Frequency
Class 0.05
Frequency
45-65Hz
EMC/EMI
300 V AC CAT II According to IEC 61010-1
+
EN 55011+A1
2010, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN61000-4-11
GENERAL
LCD Display
+
Language Support
Turkish, English, Russian
Password Protection
+
Voltage Transformer Ratio (VTR)
1 - 5000
Current Transformer Ratio (CTR)
1 - 5000
Measurements per Period
512
LCD Refresh Rate
1 sn.
Networks
TT, TN, IT
Signal Waveforms
+
Battery
+
Real-Time Clock
+
Four-Quadrant Measurement
4
Demand Period
1-60 min. adjustable
Phase Diagram
+
Min./Max. Demand Values
+
Protection Class
Front IP40 / Rear IP20
Weight (g)
428
Mounting Type
Panel Mount
POWER SUPPLY
Voltage
85-300V AC / 85-300V DC
Consumption
<3VA AC / <2.5W DC
COMMUNICATION
Protocol
Modbus RTU
Parity
None
Stop Bit
1
Insulation
2750V RMS
ENERGY MEASUREMENT
Multiple Sub-Tariffs (Peak, On-Peak, Off-Peak)
+
3-Phase Energy Measurement
+
Number of Tariffs
2
CURRENT MEASUREMENT INPUT
Measurement Range
10mA - 6A AC
Voltage Fluctuation Measurement
2 kV
Intermittent Overload
100 A for 1 sec
Sampling Frequency Between 45-65 Hz
25.6 kHz
VOLTAGE MEASUREMENT INPUT
Measuring Range (L-N)
1-300 Vrms
Measuring Range (L-L)
2-500 Vrms
Frequency Measurement Range
45-65 Hz
Sampling Frequency Between 45-65 Hz
25.6 kHz
POWER QUALITY MEASUREMENTS
THD (Voltage)
+
THD (Current)
+
Harmonics for Current and Voltage Phases
Up to 51st
MEASURING ACCURACY (IEC 61557-12)
Total Active Power
Class 0.2
Total Reactive Power
Class 1
Total Reactive Energy
Class 2
Current
Class 0.2
Neutral Current
Class 0.5
Voltage
Class 0.2
Power Factor
Class 0.5
Total Apparent Power
Class 0.2
Total Active Energy
Class 0.5
MEASURING ACCURACY (IEC 62053-22)
Total Active Energy
Class 0.2S
MEASURING ACCURACY (IEC 62053-23)
Total Reactive Energy
Class 2
ALARM RELAY OUTPUTS
Number of Outputs
2
type
NO (SPST)
Max. Switching Current
10 A
Max. Switching Voltage
250 VAC
Max. Switching Power
1250 VA
DIAGRAMS
3-Wire (with 2 CT) - Note
CTs can be connected to any phase. In the figure, they are connected to Phase-1 and Phase-3.
Single Phase (with 1 CT) - Note
CT and VT can be connected to any phase. In the figure, they are connected to Phase-1.
TIME-STAMPED DATA STORAGE
Hourly Records
1920 Hours x 68 Different Paramaters
Daily Records
240 Days x 68 Different Paramaters
Monthly Records
36 Months x 68 Different Parameters
Alarm Records
50
DIGITAL OUTPUT
Insulation Level
5000 Vrms
Number of Outputs
2
type
Transistör
Voltage Switching Range
5-30 VDC
Minimum Switching Frequency
20 Hz, 50 ms
DIGITAL INPUT
Number of Inputs
2
Insulation Level
5000 Vrms
Minimum Counting Frequency
100 Hz, 10 ms
Input Type
Dry Contact
CABLE CROSS SECTIONS (POWER SUPPLY, VOLTAGE, CURRENT, RELAY OUTPUTS)
With Ferrule
2.5mm² - 14AWG
Without Ferrule
4mm² - 12AWG, 2x1.5mm² - 2x16AWG
CABLE CROSS SECTIONS (DIGITAL I/O, RS485, ANALOG OUTPUTS)
With Ferrule
1.5mm² - 16AWG
Without Ferrule
1.5mm² - 16AWG, 2x0.75mm² - 2x18AWG
ANALOG OUTPUT
Number of Outputs
2
Output Ranges (0-5V, 0-10V, ±5V, ±10V, 0-20mA, 4-20mA)
Var
Insulation
Isolated

CE

UKCA

UL