RAPIDUS 118

SKU: 606064

Power Factor Controller

How can I find pricing information?

To access product pricing information, create an order list and contact us.

Min. order quantity : 1
Packing unit : 1 pcs.
pcs.

Product Files

×
Technical Information Sheet (TDS) pdf

Download product certificates

×
CE DECLARATION PDF
UKCA DECLARATION PDF
  • Pick up from the Woodmart Store

To pick up today

Free

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

Free

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

Free

  • Warranty 1 year
  • Free 30-Day returns
Commercial Information
Product Sales Code
606064
Packing Unit
1 pcs.
Customs Tariff No.
903289000000
Weight per piece (inc. packing)
0.94 kg.

Power Factor Controller

PRODUCT SPECIFICATIONS

THD (Voltage)
+
THD (Current)
+

CONNECTION DATA

Connection Type
L-L L-N

GENERAL

Measurement System
LCD Display
+
Language Support
Turkish, English
Password Protection
+
Voltage Transformer Ratio (VTR)
1 - 999.9
Current Transformer Ratio (CTR)
1 - 5.000
Measurements per Period
512
LCD Refresh Rate
<0.5 sec. sn.
Networks
TT, TN,

MECHANICAL SPECIFICATIONS

Weight (g)
0,94
Protection Class
Front IP40 / Rear IP20
Mounting Method
Panel Mount
Pack Quantity
1

ENVIRONMENTAL CONDITIONS

Operating Temperature
-20°C +55°C
Storage Temperature
-30°C +80°C
Relative Humidity (Non-condensing)
Max. 95%

COMMUNICATION

Protocol
--
Baud Rate
--
Parity
---
Stop Bit
--
Slave ID
--
Insulation
--

CURRENT MEASUREMENT INPUT

Measurement Range
10mA-6A AC
Overvoltage Category
300 V Cat III
Power Consumption
<0.2 VA
Intermittent Overload
100A for 1 sec.
Sampling Frequency Between 45-65 Hz
25.6 kHz

INPUTS AND OUTPUTS

Digital Outputs
--
Analog Outputs
--

STEP CONFIGURATIONS

Manual Definition
+
Predefined
1-1-1-1, 1-2-2-2, 1-2-4-4
Power (kVAr)
0.00-1000 adjustable
Type
3Ø capacitor, 1Ø capacitor

POWER FACTOR SETTINGS

Target 1 cos φ
0.8 cap. to 0.8 ind. adjustable
Target 2 cos φ
0.8 cap. to 0.8 ind. adjustable
Dual cos φ Target
+
Four-Quadrant Operation for Generators
+

VOLTAGE MEASUREMENT INPUT

Overvoltage Category
300 V Cat III
L-N Measurement Range
120...510V AC ±10%
L-L Measurement Range
120...510V AC ±10%
Frequency Measurement Range
45-65 Hz
Power Consumption
<0.2 VA
Sampling Frequency Between 45-65 Hz
25.6 kHz

MEASUREMENT ACCURACY IEC 61557-12

Total Active Power
Class 0.5
Total Reactive Power
Class 1
Total Reactive Energy
Class 2
Frequency
Class 0.1
Current
Class 0.5
Neutral Current
Class 0.5
Voltage
Class 0.2
Power Factor
Class 0.5
THDv / THDi
Class 1
Total Apparent Power
Class 0.5
Total Active Energy
Class 0.5S

MEASUREMENT ACCURACY IEC 62053-22

Total Active Energy
Class 0.5S

MEASUREMENT ACCURACY IEC 62053-23

Total Reactive Energy
Class 2

POWER FACTOR CORRECTION RELAY OUTPUTS

Number of Outputs
8
Type
NO (SPST)
Max. Switching Current
2A
Max. Switching Voltage
250VAC
Max. Switching Power
1250VA
Mechanical Service Life
= 10.0000000 operations
Electrical Service Life (NO Contact)
5×104(5A@250VAC) 1×105(5A@30VDC)

ALARM RELAY OUTPUTS

Number of Outputs
2
Type
NO (SPST)
Max. Switching Current
4A
Max. Switching Voltage
250 VAC
Max. Switching Power
1250 VA
Mechanical Service Life
= 10.0000000 operations
Electrical Service Life (NO Contact)
5×104(5A@250VAC) 1×105(5A@30VDC)

GENERATOR DAY/NIGHT INPUT

Number of Inputs
1
Frequency
45-65Hz
Input
95-240VAC

CABLE CROSS-SECTIONS

Voltage, Current, All Relay Outputs, Generator Input
Yüksüklü 2.5mm² - 14AWG
RS485
----

Diagrams

Mains Connection
+
Step Output Connections
+

POWER SUPPLY

Backup Power Input
--
Voltage
La-Lb den 120...510V AC ±10%
Frequency
45-65Hz
Consumption
< 10VA

POWER FACTOR CORRECTION MODES

Rapidus Smart Control Mode
+
Manual
+

EMC/EMI

EN 61000-6-1
2011
CE
UKRAYNA

PRODUCT SPECIFICATIONS

THD (Voltage)
+
THD (Current)
+

CONNECTION DATA

Connection Type
L-L L-N

GENERAL

Measurement System
LCD Display
+
Language Support
Turkish, English
Password Protection
+
Voltage Transformer Ratio (VTR)
1 - 999.9
Current Transformer Ratio (CTR)
1 - 5.000
Measurements per Period
512
LCD Refresh Rate
<0.5 sec. sn.
Networks
TT, TN,

MECHANICAL SPECIFICATIONS

Weight (g)
0,94
Protection Class
Front IP40 / Rear IP20
Mounting Method
Panel Mount
Pack Quantity
1

ENVIRONMENTAL CONDITIONS

Operating Temperature
-20°C +55°C
Storage Temperature
-30°C +80°C
Relative Humidity (Non-condensing)
Max. 95%

COMMUNICATION

Protocol
--
Baud Rate
--
Parity
---
Stop Bit
--
Slave ID
--
Insulation
--

CURRENT MEASUREMENT INPUT

Measurement Range
10mA-6A AC
Overvoltage Category
300 V Cat III
Power Consumption
<0.2 VA
Intermittent Overload
100A for 1 sec.
Sampling Frequency Between 45-65 Hz
25.6 kHz

INPUTS AND OUTPUTS

Digital Outputs
--
Analog Outputs
--

STEP CONFIGURATIONS

Manual Definition
+
Predefined
1-1-1-1, 1-2-2-2, 1-2-4-4
Power (kVAr)
0.00-1000 adjustable
Type
3Ø capacitor, 1Ø capacitor

POWER FACTOR SETTINGS

Target 1 cos φ
0.8 cap. to 0.8 ind. adjustable
Target 2 cos φ
0.8 cap. to 0.8 ind. adjustable
Dual cos φ Target
+
Four-Quadrant Operation for Generators
+

VOLTAGE MEASUREMENT INPUT

Overvoltage Category
300 V Cat III
L-N Measurement Range
120...510V AC ±10%
L-L Measurement Range
120...510V AC ±10%
Frequency Measurement Range
45-65 Hz
Power Consumption
<0.2 VA
Sampling Frequency Between 45-65 Hz
25.6 kHz

MEASUREMENT ACCURACY IEC 61557-12

Total Active Power
Class 0.5
Total Reactive Power
Class 1
Total Reactive Energy
Class 2
Frequency
Class 0.1
Current
Class 0.5
Neutral Current
Class 0.5
Voltage
Class 0.2
Power Factor
Class 0.5
THDv / THDi
Class 1
Total Apparent Power
Class 0.5
Total Active Energy
Class 0.5S

MEASUREMENT ACCURACY IEC 62053-22

Total Active Energy
Class 0.5S

MEASUREMENT ACCURACY IEC 62053-23

Total Reactive Energy
Class 2

POWER FACTOR CORRECTION RELAY OUTPUTS

Number of Outputs
8
Type
NO (SPST)
Max. Switching Current
2A
Max. Switching Voltage
250VAC
Max. Switching Power
1250VA
Mechanical Service Life
= 10.0000000 operations
Electrical Service Life (NO Contact)
5×104(5A@250VAC) 1×105(5A@30VDC)

ALARM RELAY OUTPUTS

Number of Outputs
2
Type
NO (SPST)
Max. Switching Current
4A
Max. Switching Voltage
250 VAC
Max. Switching Power
1250 VA
Mechanical Service Life
= 10.0000000 operations
Electrical Service Life (NO Contact)
5×104(5A@250VAC) 1×105(5A@30VDC)

GENERATOR DAY/NIGHT INPUT

Number of Inputs
1
Frequency
45-65Hz
Input
95-240VAC

CABLE CROSS-SECTIONS

Voltage, Current, All Relay Outputs, Generator Input
Yüksüklü 2.5mm² - 14AWG
RS485
----

Diagrams

Mains Connection
+
Step Output Connections
+

POWER SUPPLY

Backup Power Input
--
Voltage
La-Lb den 120...510V AC ±10%
Frequency
45-65Hz
Consumption
< 10VA

POWER FACTOR CORRECTION MODES

Rapidus Smart Control Mode
+
Manual
+

EMC/EMI

EN 61000-6-1
2011
CE
UKRAYNA