145-1M-V2
SKU:
606361
1Ø Energy Meter
How can I find pricing information?
To access product pricing information, create an order list and contact us.
Min. order quantity : 1
Packing unit : 1 pcs.
-
Pick up from the Woodmart Store
To pick up today
Free
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
Free
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
Free
-
Warranty 1 year
-
Free 30-Day returns
Commercial Information
Product Sales Code
606361
Packing Unit
1 pcs.
Customs Tariff No.
903032009011
Weight per piece (inc. packing)
0.08 kg.
Product Description
1Ø Energy Meter
Technical Information
GENERAL
Connection Type
1P2W
Real-Time Clock
-
Current Connection Type
Direkt Baglantili (45A ya kadar)
Alarm
+
MECHANICAL SPECIFICATIONS
Weight (g)
80
Protection Class
IP20
Mounting Method
Rail Mount
ENVIRONMENTAL CONDITIONS
Operating Temperature
-25°C +50°C
Storage Temperature
-25°C +70°C
Relative Humidity (Non-condensing)
Max. 80% (no condensation)
COMMUNICATION
Protocol
Modbus RTU
Baud Rate
1200-115200
Parity
Odd, Even, None
Stop Bit
1
Slave ID
1-247
Insulation
2750V RMS
CURRENT MEASUREMENT INPUT
Measurement Range
0,25 .. 45A
ENERGY MEASUREMENT
Number of Tariffs
2
Number of Sub-Tariffs
-
Number of Reactive Measurement Quadrants
2
Energy Measurement Type
Import & Export kWh-kVArh
VOLTAGE MEASUREMENT INPUT
L-N Measurement Range
100-300V AC
L-L Measurement Range
-
POWER QUALITY MEASUREMENTS
Harmonic Measurement (Current and Voltage)
-
THDi
+
THDv
+
BASIC ELECTRICAL MEASUREMENTS
Current
+
Voltage
+
Frequency
+
Active Power
+
Reactive Power
+
Apparent Power
+
MEASUREMENT CLASS
IEC 62053-21
Class 1
MEASUREMENT
Demand
+
POWER SUPPLY
Voltage
100-300V AC
Frequency
45-65Hz
Consumption
<3VA AC
Certificates

CE

UKCA

UL
Accessories
GENERAL
Connection Type
1P2W
Real-Time Clock
-
Current Connection Type
Direkt Baglantili (45A ya kadar)
Alarm
+
MECHANICAL SPECIFICATIONS
Weight (g)
80
Protection Class
IP20
Mounting Method
Rail Mount
ENVIRONMENTAL CONDITIONS
Operating Temperature
-25°C +50°C
Storage Temperature
-25°C +70°C
Relative Humidity (Non-condensing)
Max. 80% (no condensation)
COMMUNICATION
Protocol
Modbus RTU
Baud Rate
1200-115200
Parity
Odd, Even, None
Stop Bit
1
Slave ID
1-247
Insulation
2750V RMS
CURRENT MEASUREMENT INPUT
Measurement Range
0,25 .. 45A
ENERGY MEASUREMENT
Number of Tariffs
2
Number of Sub-Tariffs
-
Number of Reactive Measurement Quadrants
2
Energy Measurement Type
Import & Export kWh-kVArh
VOLTAGE MEASUREMENT INPUT
L-N Measurement Range
100-300V AC
L-L Measurement Range
-
POWER QUALITY MEASUREMENTS
Harmonic Measurement (Current and Voltage)
-
THDi
+
THDv
+
BASIC ELECTRICAL MEASUREMENTS
Current
+
Voltage
+
Frequency
+
Active Power
+
Reactive Power
+
Apparent Power
+
MEASUREMENT CLASS
IEC 62053-21
Class 1
MEASUREMENT
Demand
+
POWER SUPPLY
Voltage
100-300V AC
Frequency
45-65Hz
Consumption
<3VA AC

CE

UKCA

UL