ECRAS 301
SKU:
606501
3Ø Electronic Multimeter
How can I find pricing information?
To access product pricing information, create an order list and contact us.
Min. order quantity : 1
Packing unit : 1 pcs.
-
Pick up from the Woodmart Store
To pick up today
Free
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
Free
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
Free
-
Warranty 1 year
-
Free 30-Day returns
Commercial Information
Product Sales Code
606501
Packing Unit
1 pcs.
Customs Tariff No.
903032009011
Product Description
3Ø Electronic Multimeter
Technical Information
GENERAL
LCD Display
-
Language Support
English
Password Protection
+
Networks
TT, TN, IT
Signal Waveforms
-
Connection Type
3P4W, 3P3W
Battery
-
Real-Time Clock
-
Demand Period
-
Pack Quantity
1
Min./Max. Data
+
Ghost Display
+
Display Refresh Period
1sn
MECHANICAL SPECIFICATIONS
Protection Class
IP54
Mounting Method
Panel Mount
ENVIRONMENTAL CONDITIONS
Operating Temperature
-25°C +70°C
Storage Temperature
-30°C +80°C
Relative Humidity (Non-condensing)
Max. 95% (no condensation)
COMMUNICATION
Protocol
-
Baud Rate
-
Parity
-
Stop Bit
-
Slave ID
-
Insulation
-
CURRENT MEASUREMENT INPUT
Measurement Range
50mA-6A AC
Overvoltage Category
300 V Cat II
Voltage Fluctuation Measurement
<2 kV
Power Consumption
<0.2 VA
Intermittent Overload
100 A for 1 sec
ENERGY MEASUREMENT
Three-Phase Energy Measurement
+
Single Energy Measurement
+
Number of Reactive Measurement Quadrants
4
VOLTAGE MEASUREMENT INPUT
Overvoltage Category
300 V Cat III
L-N Measurement Range
10-300 Vrms
L-L Measurement Range
17-500 Vrms
Frequency Measurement Range
45-65 Hz
Power Consumption
<0.1 VA
POWER QUALITY MEASUREMENTS
Harmonic Measurement (Current and Voltage)
-
THDi
-
THDv
-
MEASUREMENT ACCURACY IEC 61557-12
Total Active Power
-
Total Reactive Power
-
Total Reactive Energy
-
Frequency
Class 0.2
Current
Class 0.5
Neutral Current
Class 0.5
Voltage
Class 0.5
Power Factor
-
THDv / THDi
-
Total Apparent Power
-
Total Active Energy
-
MEASUREMENT ACCURACY IEC 62053-22
Total Active Energy
-
MEASUREMENT ACCURACY IEC 62053-23
Total Reactive Energy
-
ALARM RELAY OUTPUTS
Number of Outputs
2 pcs.
Max. Switching Current
10 A
Max. Switching Voltage
250 VAC
Max. Switching Power
1250 VA
BASIC ELECTRICAL MEASUREMENTS
Current
+
Voltage
+
Frequency
+
CABLE CROSS-SECTIONS - CURRENT
Stranded
4mm² - 12AWG, 2x1.5mm² - 2x16AWG
Solid
4mm² - 12AWG, 2x1.5mm² - 2x16AWG
POWER SUPPLY
Voltage
85-300V AC - 85-300V DC
Frequency
45-65Hz
Consumption
<3VA AC - <2.5W DC
CABLE CROSS SECTIONS (POWER SUPPLY, VOLTAGE, RELAY)
Stranded
2.5mm² - 14AWG
Solid
4mm² - 12AWG, 2x1.5mm² - 2x16AWG
CABLE CROSS SECTIONS (DIGITAL I/O, RS485, ANALOG OUTPUT)
Stranded
1.5mm² - 16AWG
Solid
4mm² - 12AWG, 2x1.5mm² - 2x16AWG
Certificates

CE

UKCA

UL
Accessories
GENERAL
LCD Display
-
Language Support
English
Password Protection
+
Networks
TT, TN, IT
Signal Waveforms
-
Connection Type
3P4W, 3P3W
Battery
-
Real-Time Clock
-
Demand Period
-
Pack Quantity
1
Min./Max. Data
+
Ghost Display
+
Display Refresh Period
1sn
MECHANICAL SPECIFICATIONS
Protection Class
IP54
Mounting Method
Panel Mount
ENVIRONMENTAL CONDITIONS
Operating Temperature
-25°C +70°C
Storage Temperature
-30°C +80°C
Relative Humidity (Non-condensing)
Max. 95% (no condensation)
COMMUNICATION
Protocol
-
Baud Rate
-
Parity
-
Stop Bit
-
Slave ID
-
Insulation
-
CURRENT MEASUREMENT INPUT
Measurement Range
50mA-6A AC
Overvoltage Category
300 V Cat II
Voltage Fluctuation Measurement
<2 kV
Power Consumption
<0.2 VA
Intermittent Overload
100 A for 1 sec
ENERGY MEASUREMENT
Three-Phase Energy Measurement
+
Single Energy Measurement
+
Number of Reactive Measurement Quadrants
4
VOLTAGE MEASUREMENT INPUT
Overvoltage Category
300 V Cat III
L-N Measurement Range
10-300 Vrms
L-L Measurement Range
17-500 Vrms
Frequency Measurement Range
45-65 Hz
Power Consumption
<0.1 VA
POWER QUALITY MEASUREMENTS
Harmonic Measurement (Current and Voltage)
-
THDi
-
THDv
-
MEASUREMENT ACCURACY IEC 61557-12
Total Active Power
-
Total Reactive Power
-
Total Reactive Energy
-
Frequency
Class 0.2
Current
Class 0.5
Neutral Current
Class 0.5
Voltage
Class 0.5
Power Factor
-
THDv / THDi
-
Total Apparent Power
-
Total Active Energy
-
MEASUREMENT ACCURACY IEC 62053-22
Total Active Energy
-
MEASUREMENT ACCURACY IEC 62053-23
Total Reactive Energy
-
ALARM RELAY OUTPUTS
Number of Outputs
2 pcs.
Max. Switching Current
10 A
Max. Switching Voltage
250 VAC
Max. Switching Power
1250 VA
BASIC ELECTRICAL MEASUREMENTS
Current
+
Voltage
+
Frequency
+
CABLE CROSS-SECTIONS - CURRENT
Stranded
4mm² - 12AWG, 2x1.5mm² - 2x16AWG
Solid
4mm² - 12AWG, 2x1.5mm² - 2x16AWG
POWER SUPPLY
Voltage
85-300V AC - 85-300V DC
Frequency
45-65Hz
Consumption
<3VA AC - <2.5W DC
CABLE CROSS SECTIONS (POWER SUPPLY, VOLTAGE, RELAY)
Stranded
2.5mm² - 14AWG
Solid
4mm² - 12AWG, 2x1.5mm² - 2x16AWG
CABLE CROSS SECTIONS (DIGITAL I/O, RS485, ANALOG OUTPUT)
Stranded
1.5mm² - 16AWG
Solid
4mm² - 12AWG, 2x1.5mm² - 2x16AWG

CE

UKCA

UL