TST 1,5 Grey

SKU: 499659

Cage Clamp Type, 1,5 mm² test

How can I find pricing information?

To access product pricing information, create an order list and contact us.

Min. order quantity : 50
Packing unit : 50 pcs.
pcs.

Download product certificates

×
CE DECLARATION PDF
UKCA DECLARATION PDF
  • Pick up from the Woodmart Store

To pick up today

Free

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

Free

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

Free

  • Warranty 1 year
  • Free 30-Day returns
Commercial Information
Product Sales Code
499659
Packing Unit
50 pcs.

Cage Clamp Type, 1,5 mm² test

PRODUCT SPECIFICATIONS

Number of Connections
1
Number of Levels
1
Insulation Material
PA
UL 94 Flammability Class
V0
Impulse Voltage Category
III
Insulation Material Group
I
Pollution Degree
3
Connection According to Standard
IEC 60947-7-1
Fire Protection in Railway Vehicles (DIN EN 45545-2 R22/R23/R24/R26)
HL 1 - HL 2 - HL 3
Continuous Operating Temperature Max.
130 °C
Continuous Operating Temperature Min.
-60 °C

ELECTRICAL SPECIFICATIONS

Nominal Impulse Voltage
8 Kv
Nominal Voltage
500 V
Nominal Current (In / Fuse)
10 A

CONNECTION DATA

Connection Type
Spring Connection
Min. Solid Conductor Cross-Sectional Area
0,08 mm²
Max. Solid Conductor Cross-Sectional Area
1,5 mm²
Conductor Cross-Section AWG/kcmil Min.
28 AWG
Conductor Cross-Section AWG/kcmil Max.
16 AWG
Min. Stranded Conductor Cross-Sectional Area
0,08 mm²
Max. Stranded Conductor Cross-Sectional Area
1,5 mm²
Min. Stranded Conductor Cross-Sectional Area with Ferrule
0,08 mm²
Max. Stranded Conductor Cross-Sectional Area with Ferrule
1,5 mm²
Min. for 2 Stranded Conductors of the Same Cross-Section with Plastic-Collared Twin Ferrule
0,5 mm²
Max. for 2 Stranded Conductors of the Same Cross-Section with Plastic-Collared Twin Ferrule
0,5 mm²
Min. Stripping Length
8 mm
Max. Stripping Length
10 mm
Internal Cylindrical Indicator
A1

DIMENSIONS

Width
4,20 mm
Length
17,67 mm
Yükseklik
52,07 mm
CE
UKCA
CSA
cULus
VDE
ATEX

Test Sockets

Product Code: 493020
TF (Ø 2)

Klemens Termal Yazıcı Etiketleri

Product Code: 810150
D-NS 4,2x6

PRODUCT SPECIFICATIONS

Number of Connections
1
Number of Levels
1
Insulation Material
PA
UL 94 Flammability Class
V0
Impulse Voltage Category
III
Insulation Material Group
I
Pollution Degree
3
Connection According to Standard
IEC 60947-7-1
Fire Protection in Railway Vehicles (DIN EN 45545-2 R22/R23/R24/R26)
HL 1 - HL 2 - HL 3
Continuous Operating Temperature Max.
130 °C
Continuous Operating Temperature Min.
-60 °C

ELECTRICAL SPECIFICATIONS

Nominal Impulse Voltage
8 Kv
Nominal Voltage
500 V
Nominal Current (In / Fuse)
10 A

CONNECTION DATA

Connection Type
Spring Connection
Min. Solid Conductor Cross-Sectional Area
0,08 mm²
Max. Solid Conductor Cross-Sectional Area
1,5 mm²
Conductor Cross-Section AWG/kcmil Min.
28 AWG
Conductor Cross-Section AWG/kcmil Max.
16 AWG
Min. Stranded Conductor Cross-Sectional Area
0,08 mm²
Max. Stranded Conductor Cross-Sectional Area
1,5 mm²
Min. Stranded Conductor Cross-Sectional Area with Ferrule
0,08 mm²
Max. Stranded Conductor Cross-Sectional Area with Ferrule
1,5 mm²
Min. for 2 Stranded Conductors of the Same Cross-Section with Plastic-Collared Twin Ferrule
0,5 mm²
Max. for 2 Stranded Conductors of the Same Cross-Section with Plastic-Collared Twin Ferrule
0,5 mm²
Min. Stripping Length
8 mm
Max. Stripping Length
10 mm
Internal Cylindrical Indicator
A1

DIMENSIONS

Width
4,20 mm
Length
17,67 mm
Yükseklik
52,07 mm
CE
UKCA
CSA
cULus
VDE
ATEX