General |
Seven Segment Display |
|
|
LCD Screen |
✔ |
|
Language Support |
--- |
|
Battery |
--- |
|
Real Time Clock |
--- |
|
Password Protection |
✔ |
|
Current Transformer Ratio |
1-5.000 |
|
Voltage Transformer Ratio |
1-5.000 |
|
Demand Period |
1-60 min. adjustable |
|
Connection Type |
3P4W, 3P3W |
|
Measurements in Quadrants |
4 |
|
Number of Measurements in a Period |
256 |
|
LCD/Display Refresh Period |
1 sec |
|
Networks |
TT, TN, IT |
|
Phasor Diagram |
--- |
|
Signal Waveforms |
--- |
|
Min./Max./Demand Values |
✔ |
Energy Measurement |
Number of Tariffs |
1 |
|
Multi Sub-Tariffs (Peak, Day and Off-Peak) |
--- |
|
1Ø Phase Energy Meters |
--- |
|
3Ø Phase Energy Meters |
✔ |
|
4 Quadrant Reactive Energy Meters |
--- |
Current Measurement Input |
Measurement Range |
10mA-6A AC |
|
Overvoltage Category |
300 V Cat II |
|
Measurement Surge Voltage |
2 kV |
|
Power Consumption |
<0.2 VA |
|
Intermittent Overload |
100A for 1 sec |
|
Sampling Frequency between 45-65 Hz |
12,8 kHz |
Voltage Measurement Input |
Overvoltage Category |
300 V Cat III |
|
Measured Range L-N |
1-300 Vrms |
|
Measured Range L-L |
2-500 Vrms |
|
Measured Frequency Range |
45-65 Hz |
|
Power Consumption |
<0.1 VA |
|
Sampling Frequency between 45-65 Hz |
12,8 kHz |
Power Quality Measurements |
Harmonics for Current and Voltage Phases |
31’e kadar |
|
THD - Voltage in % |
✔ |
|
THD - Current in % |
✔ |
Other Measurements |
Run Hour (Operating Time for Load in Hours) |
✔ |
|
On Hour (Operating Time for Meter in Hours) |
✔ |
|
Int Counter (Number of Power Interruptions) |
✔ |
Measurement Accuracy |
According to IEC 61557-12 |
Total Active Power |
Class 0.5 |
|
|
Total Reactive Power |
Class 1 |
|
|
Total Apparent Power |
Class 0.5 |
|
|
Total Active Energy |
Class 0.5 |
|
|
Total Reactive Energy |
Class 2 |
|
|
Frequency |
Class 0.1 |
|
|
Current |
Class 0.5 |
|
|
Neutral Current |
Class 0.5 |
|
|
Voltage |
Class 0.2 |
|
|
Power Factor |
Class 0.5 |
|
|
THDV, THDI |
Class 1 |
|
According to IEC 62053-22 |
Total Active Energy |
Class 0.5S |
|
According to IEC 62053-23 |
Total Reactive Energy |
Class 2 |
Inputs and Outputs |
Alarm Relay Outputs |
Number of Outputs |
--- |
|
|
Type |
--- |
|
|
Max. Switching Current |
--- |
|
|
Max. Switching Voltage |
--- |
|
|
Max. Switching Power |
--- |
|
Digital Inputs |
Number of Inputs |
--- |
|
|
Minimum Counting Frequency |
--- |
|
|
Input Present or Not |
--- |
|
|
Isolation Level |
--- |
|
Digital Outputs |
Number of Outputs |
--- |
|
|
Type |
--- |
|
|
Switching Voltage Range |
--- |
|
|
Minimum Switching Frequency |
--- |
|
|
Isolation Level |
--- |
|
Analog Outputs |
Number of Outputs |
--- |
|
|
Range of Outputs 0-5 V, 0-10 V, -5-5 V, -10-10V, 0-20 mA, 4-20 mA |
--- |
|
|
Isolation |
2750V RMS |
Supply |
Voltage |
AC |
85-300V |
|
|
DC |
85-300V |
|
Consumption |
AC |
<4.5VA |
|
|
DC |
<2W |
Supply |
Frequency |
45-65Hz |
Data Logging with timestamp |
Min./Max./Avg. Values |
Hourly Records |
--- |
|
|
Daily Records |
--- |
|
|
Monthly Records |
--- |
Data Logging with timestamp |
Demand |
--- |
|
Alarm Records |
--- |
Communication |
Protocol |
Modbus RTU |
|
Baud Rate |
1200-57600 bps adjustable |
|
Parity Number |
Odd, Even, None |
|
Stop Bit |
1 |
|
Address |
1-247 |
|
Isolation |
2750V RMS |
Mechanical Properties |
Weight (g) |
378 |
|
Protection Class |
Front IP40 / Rear IP20 |
|
Mounting Type |
Panel Mount |
Cable Cross Sections |
Supply, Voltage, Current, Relay Outputs |
Stranded: |
2,5 mm2 - 14AWG |
|
|
Solid: |
4mm2-12 AWG, 2x1.5 mm2- 2x16 AWG |
|
Digital I/O, RS 485, Analog Output |
Stranded: |
1,5 mm2-16AWG |
|
|
Solid: |
1.5 mm2-16 AWG, 2x0.75 mm2- 2x18 AWG |
Ambient Conditions |
Operating Temperature |
-20 to +70°C |
|
Storing Temperature |
-30 to +80°C |
|
Relative Humidity (No Condensation) |
Maks. 95% |
EMC-EMI |
300 VAC CAT II according to IEC 61010-1 |
✔ |
|
EN 55011/A1:2010, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN61000-4-11 |
✔ |
General |
|
|
|
Dimensions |
|